As-built plans.  


Latest version.
  • Prior to the acceptance by the Borough of any street or other improvement on a site plan, there shall be filed with the Borough Engineer one Mylar original as-built plan and profiles drawn to a scale of not less than one inch equals 50 feet horizontally and one inch equals five feet vertically, which plan and profiles shall be based on a final survey. Such drawings shall show how the streets and other improvements were actually constructed or installed. The following data must be shown with measurements from the property lines.
    a. 
    Plans and profiles of the streets showing elevations as constructed, and reference bench marks.
    b. 
    Plans and profiles of sanitary and storm sewers showing elevations of inverts of manholes and catch basins and elevations of inlet gratings and manhole rims.
    c. 
    The location of all house connections to the sanitary sewer with reference dimensions to cleanout connections.
    d. 
    The location of all water and gas mains together with all valves.
Ord. No. 773 § 2; 1972 Code § 130.418